Homepage | Sitemap | Contact Us | עברית
News & Updates
Company's Solutions
VCI 2000 Anti Corrosion Packaging
Zipper Profiles
Anti Static Packing
Anti Fog Packaging – General Information
Bio Fresh Packaging
Zipper Bags
Shopping Bags (reinforced handle)
Hanging Bags
For more details

בננה-באנר

Absorption Testing – Bio Fresh

Results of bio fresh absorption testing:

 

The Case in Mention

A test to examine the ability of the additive Bio Fresh Masterbatch to absorb ethanol and ethylene at room temperature

 

The Tested Material

5 kg of rolls of white Masterbarch, about 3 mm in diameter, about 3 mm long, sealed in a polyethylene bag.

The Method of Testing

Determining absorption capacity

5 to 10 grams of Masterbatch were dried in a drying oven for 3 hours at a temperature of 105ºC.  Afterwards, the contents were placed into to an open container inside the drying oven (a volume of about 4.8 liters).

 

Determining the Level of Ethylene Absorption

The drying oven was flushed with ethylene and stored for a total of 30 days.  The level of ethylene absorption was determined by measuring weight and by gas chromatography (by means of the Headspace technology – heating up to 90ºC for 30 minutes).  Device number 319, dividing column B:  4 determining tests were conducted each time.

 

Determining the Level of Ethanol Absorption

A container filled with ethanol was placed into a drying oven and stored for a total of 25 days. The level of ethanol absorption was determined by measuring weight and by gas chromatography (by means of the Headspace technology – heating up to 90ºC for 30 minutes).  Device number 319, dividing column GS-B:  4 determining tests were conducted each time.

 

 

 

Test Results

Determining Ethanol and Ethylene Absorption Levels by Measuring Weight

 

Table 1:  Determining by measuring weights of ethanol after a storage period of 25 days

Sample No.

Pre-test Weight

Post-test Weight

Added Weight

(grams)

Added Weight

(%)

1

7.387

7.6201

0.233

3.16

2

7.4052

7.6441

0.2389

3.23

3

6.584

6.7959

0.2119

3.22

4

7.3344

7.5679

0.2335

3.18

MW

 

 

 

3.2

S

 

 

 

0.03

 

 

 

Table 2:  Determining by measuring weights of ethylene after a storage period of 30 days

Sample No.

Pre-test Weight

Post-test Weight

Added Weight

(grams)

Added Weight

(%)

1

5.8927

5.9205

0.0278

0.47

2

5.7042

5.732

0.0278

0.49

3

6.0087

6.053

0.0443

0.74

4

6.7106

6.7566

0.046

0.69

MW

 

 

 

0.6

S

 

 

 

0.14

 

Determining Ethanol and Ethylene Absorption Levels by Gas Chromatography

 

 

Table 3:  Determining by gas chromatography of ethanol after a storage period of 25 days

Sample No.

Pre-test Weight

Content (mp)

Content (%)

1

1.0144

22.4

2.2

2

1.2207

28.8

2.36

3

1.0335

22.3

2.16

4

0.9843

18.1

1.84

MW

 

 

2.14

S

 

 

0.22

 

 

Table 4:  Determining by gas chromatography of ethylene after a storage period of 30 days

Sample No.

Pre-test Weight

Content (mp)

Content (%)

1

1.604

2.1

0.6

2

1.0377

6.3

0.6

3

1.3068

8.1

0.62

4

1.5003

9.2

0.61

MW

 

 

0.54

S

 

 

0.14

 

 

Conclusion

The tested Bio Fresh Masterbatch indicated an ethanol absorption level of 2.14 +/-0.22 Gew % after a storage period of 25 days at room temperature in an ethanol saturated atmosphere.  The ethylene absorption level was 0.54 +/- 0.14 Gew % after a storage period of 30 days at room temperature in an ethylene atmosphere.  The measured values noted for weights, particularly the weights of ethanol, were somewhat higher than the values noted from the gas chromatography testing.  This is due to the fact that water absorption is also measured in this method of measuring weights.

↑Back To Top Back To Homepage